Controls / Electrical accessories

Controls are mandatory for all automatic fire protection systems.

In case of malfunction, the smoke and fire protection closures would not fulfil their task and therefore not contribute to fire fighting. They evaluate the fire detection signals and trigger the closures independently of energy.

Characteristics

  • building authorities approved locking device

  • 24V or 230V motor control units, roll-down without external power supply

  • smoke switch / smoke detector

Type

RZ-24 locking system and motor terminal box
230V Fail Safe

Release unit for textile smoke barriers and fire protection closures. With membrane keypad for operation and visual and acoustic display. Integrated manual release button.

 

With the optionally available power pack, short-term power grid failures (a few minutes) can be bridged e.g. until a backup generator starts up.

 

Connection and evaluation of a fire alarm panel signal possible, connection options for fire detection elements, additional manual release button.

RZ-24
MS-15/23

MS-15/23
230 V Failsafe

Central- / group control of smoke barriers and fire protection closures

230V AC Fail Safe Power supply in case of power grid failures via maintenance-free battery pack, automatic closing / roll-down in case of an alarm.

​

Potential-free signal output for forwarding to superordinated control, evaluation of on-site, potential-free fire alarm signals.

​

Connection options for fire detection elements and manual release buttons.

MS-15/17
24 V Failsafe

Central / group control of smoke barriers and fire protection closures 24V DC Fail Safe Battery-buffered power supply, 24 V DC with voltage monitoring, automatic closing / roll-down in case of alarm or power grid failure after approx. 2 minutes.

​

Potential-free signal output for forwarding to superordinated control, evaluation of on-site, potential-free fire alarm signals.

 

Connection options for fire detection elements and manual release buttons.

MS-15/17B

MS-15/24

24 V Standard

Central / group control of smoke barriers and fire protection closures 24V DC Standard Battery-buffered power supply, 24 V DC with voltage monitoring, automatic closing in case of alarm or power failure after approx. 2 minutes.

 

Potential-free signal output for forwarding to superordinated control, connection options for fire detection elements and manual release buttons.

 

Connection options for fire detection elements and manual release buttons.

MS-15/24B

Manual release / push button DKT PRO

Manual alarm triggering.

 

Red trigger button and reset button concealed from the outside.

 

Protected against unauthorised or unintentional actuation by means of a glass pane.

 

Aluminium casing, IP40, case colour orange.

DKT PRO

Manual release / push button DKT 02

Manual alarm triggering.

 

Red trigger button and reset button concealed from the outside.

 

Protected against unauthorised or unintentional actuation by means of a glass pane.

 

Plastic casing, IP20.

 

Case available in following colours : yellow, grey and orange.

S65 optical smoke detector

The Series 65 optical smoke detector comes with a pulsating LED and a photodiode inside the smoke detector housing.

DKT 02
Optischer Rauchmelder S65

Thermal differential detector S65

The Series 65 thermal differential detector monitors the temperature of the ambient air using a dual thermistor network that outputs voltage proportional to the air temperature.

Thermodifferentialmelder S65